Manual Reference Pages  -  MODBUS_READ_INPUT_BITS (3)

.ds Aq ’

NAME

modbus_read_input_bits - read many input bits

CONTENTS

SYNOPSIS

int modbus_read_input_bits(modbus_t *ctx, int addr, int nb, uint8_t *dest);

DESCRIPTION

The modbus_read_input_bits() function shall read the content of the nb input bits to the address addr of the remote device. The result of reading is stored in dest array as unsigned bytes (8 bits) set to TRUE or FALSE.

You must take care to allocate enough memory to store the results in dest (at least nb * sizeof(uint8_t)).

The function uses the Modbus function code 0x02 (read input status).

RETURN VALUE

The modbus_read_input_status() function shall return the number of read input status if successful. Otherwise it shall return -1 and set errno.

ERRORS

EMBMDATA

Too many discrete inputs requested

SEE ALSO

modbus_read_input_registers(3)

AUTHORS

The libmodbus documentation was written by St\(&#146;ephane Raimbault <\m[blue]stephane.raimbault@gmail.com\m[][1]>

NOTES

1. stephane.raimbault@gmail.com  mailto:stephane.raimbault@gmail.com
Search for    or go to Top of page |  Section 3 |  Main Index


libmodbus 3&.1&.0 MODBUS_READ_INPUT_BI (3) 10/06/2013

Powered by GSP Visit the GSP FreeBSD Man Page Interface.
Output converted with manServer 1.07.