GSP
Quick Navigator

Search Site

Unix VPS
A - Starter
B - Basic
C - Preferred
D - Commercial
MPS - Dedicated
Previous VPSs
* Sign Up! *

Support
Contact Us
Online Help
Handbooks
Domain Status
Man Pages

FAQ
Virtual Servers
Pricing
Billing
Technical

Network
Facilities
Connectivity
Topology Map

Miscellaneous
Server Agreement
Year 2038
Credits
 

USA Flag

 

 

Man Pages
NVME-ADMIN-PASSTHR(1) NVMe Manual NVME-ADMIN-PASSTHR(1)

nvme-admin-passthru - Submit an arbitrary admin command, return results

nvme-admin-passthru <device> [--opcode=<opcode> | -O <opcode>]

[--flags=<flags> | -f <flags>] [-rsvd=<rsvd> | -R <rsvd>]
[--namespace-id=<nsid> | -n <nsid>] [--cdw2=<cdw2> | -2 <cdw2>]
[--cdw3=<cdw3> | -3 <cdw3>] [--cdw10=<cdw10> | -4 <cdw10>]
[--cdw11=<cdw11> | -5 <cdw11>] [--cdw12=<cdw12> | -6 <cdw12>]
[--cdw13=<cdw13> | -7 <cdw13>] [--cdw14=<cdw14> | -8 <cdw14>]
[--cdw15=<cdw15> | -9 <cdw15>]
[--data-len=<data-len> | -l <data-len>]
[--metadata-len=<len> | -m <len>]
[--input-file=<file> | -i <file>]
[--read | -r] [--write | -w]
[--timeout=<timeout> | -t <timeout>]
[--show-command | -s]
[--dry-run | -d]
[--raw-binary | -b]
[--prefill=<prefill> | -p <prefill>]
[--latency | -T]
[--output-format=<fmt> | -o <fmt>] [--verbose | -v]

Submits an arbitrary NVMe admin command and returns the applicable results. This may be the simply the commands result and status, or may also include a buffer if the command returns one. This command does no interpretation of the opcodes or options.

The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1).

On success, the returned structure (if applicable) may be returned in one of several ways depending on the option flags; the structure may printed by the program as a hex dump, or may be returned as a raw buffer printed to stdout for another program to parse.

-O <opcode>, --opcode=<opcode>

The NVMe opcode to send to the device in the command

-f <flags>, --flags=<flags>

The NVMe command flags to send to the device in the command

-R <rsvd>, --rsvd=<rsvd>

The value for the reserved field in the command.

-n <nsid>, --namespace-id=<nsid>

The value for the ns-id in the command.

-[2-9] <cdw>, --cdw[2-3,10-15]=<cdw>

Specifies the command dword value for that specified entry in the command

-r, --read, -w, --write

Used for the data-direction for the command and required for commands sending/receiving data. Don’t use both read and write at the same time.

-i <file>, --input-file=<file>

If the command is a data-out (write) command, use this file to fill the buffer sent to the device. If no file is given, assumed to use STDIN.

-l <data-len>, --data-len=<data-len>

The data length for the buffer used for this command.

-m <data-len>, --metadata-len=<data-len>

The metadata length for the buffer used for this command.

-s, --show-cmd

Print out the command to be sent.

-d, --dry-run

Do not actually send the command. If want to use --dry-run option, --show-cmd option must be set. Otherwise --dry-run option will be ignored.

-b, --raw-binary

Print the raw returned buffer to stdout if the command returns a structure.

-p, --prefill

Prefill the buffer with a predetermined byte value. Defaults to 0. This may be useful if the data you are writing is shorter than the required buffer, and you need to pad it with a known value. It may also be useful if you need to confirm if a device is overwriting a buffer for a data-in command.

-T, --latency

Print out the latency the IOCTL took (in us).

-o <fmt>, --output-format=<fmt>

Set the reporting format to normal, json or binary. Only one output format can be used at a time.

-v, --verbose

Increase the information detail in the output.

-t <timeout>, --timeout=<timeout>

Override default timeout value. In milliseconds.

•The following will run the admin command with opcode=6 and cdw10=1, which corresponds to an identify controller command. This example requires the data-len param be 4096, which is the size of the returned structure. The -r option is used because it is a data-in command

# nvme admin-passthru /dev/nvme0 --opcode=06 --data-len=4096 --cdw10=1 -r

•Or if you want to save that structure to a file:

# nvme admin-passthru /dev/nvme0 --opcode=06 --data-len=4096 --cdw10=1 -r -b > id_ns.raw

Part of the nvme-user suite

10/31/2024 NVMe

Search for    or go to Top of page |  Section 1 |  Main Index

Powered by GSP Visit the GSP FreeBSD Man Page Interface.