GSP
Quick Navigator

Search Site

Unix VPS
A - Starter
B - Basic
C - Preferred
D - Commercial
MPS - Dedicated
Previous VPSs
* Sign Up! *

Support
Contact Us
Online Help
Handbooks
Domain Status
Man Pages

FAQ
Virtual Servers
Pricing
Billing
Technical

Network
Facilities
Connectivity
Topology Map

Miscellaneous
Server Agreement
Year 2038
Credits
 

USA Flag

 

 

Man Pages
MODBUS_READ_INPUT_RE(3) libmodbus Manual MODBUS_READ_INPUT_RE(3)

modbus_read_input_registers - read many input registers

int modbus_read_input_registers(modbus_t *ctx, int addr, int nb, uint16_t *dest);

The modbus_read_input_registers() function shall read the content of the nb input registers to address addr of the remote device. The result of the reading is stored in dest array as word values (16 bits).

You must take care to allocate enough memory to store the results in dest (at least nb * sizeof(uint16_t)).

The function uses the Modbus function code 0x04 (read input registers). The holding registers and input registers have different historical meaning, but nowadays it’s more common to use holding registers only.

The function shall return the number of read input registers if successful. Otherwise it shall return -1 and set errno.

EMBMDATA
Too many bits requested

modbus_read_input_bits(3) modbus_write_register(3) modbus_write_registers(3)

The libmodbus documentation was written by Stéphane Raimbault <stephane.raimbault@gmail.com>
04/09/2022 libmodbus v3.1.6

Search for    or go to Top of page |  Section 3 |  Main Index

Powered by GSP Visit the GSP FreeBSD Man Page Interface.
Output converted with ManDoc.