NAMEnvme-ocp-internal-log - Conditionally retrieves 07h Telemetry Host-Initiated log, C9h OCP Strings Log from an NVMe device or from user-specified file path. Takes retrieved logs and decodes into human-readable output format specified by user. SYNOPSISnvme ocp internal-log <device> DESCRIPTIONConditionally retrieves 07h Telemetry Host-Initiated log, C9h OCP Strings Log from an NVMe device or from user-specified file path. Takes retrieved logs and decodes (or) parses into human-readable output format specified by user. The <device> parameter is mandatory and may be either the NVMe character device (ex: /dev/nvme0), or a namespace block device (ex: /dev/nvme0n1). This will only work on OCP compliant devices supporting this feature. Results for any other device are undefined. On success it returns 0, error code otherwise. OPTIONS-l <file>, --telemetry-log=<file> File name to existing Telemetry Host-Initiated raw binary
data to be used. If no path is specified, a live retrieval of payload on
<device> will be performed.
-s <file>, --string-log=<file> File name to existing OCP String Log raw binary data to
be used. If no path is specified, a live retrieval of payload on
<device> will be performed.
-o <file>, --output-file=<file> Filepath name to where human-readable output data will be
saved to.
-f <fmt>, --output-format=<fmt> Set the reporting format to normal, json.
Only one output format can be used at a time, the default value is
json.
-a <da>, --data-area=<da> Retrieves the specific data area requested. Valid inputs
are 1,2. If this option is not specified, the default value is 1.
-t <type>, --telemetry-type=<type> If set to 1, controller shall capture the Telemetry
Host-Initiated data representing the internal state of the controller at the
time the associated Get Log Page command is processed. If cleared to 0,
controller shall not update this data.
EXAMPLES•Retrieve in both OCP String Log and Telemetry
Host-Initiated Log from device. Decode default data-area(s) in default format
and output to console.
# nvme ocp internal-log /dev/nvme0 •Retrieve Telemetry Host-Initiated data, reads in
the OCP String Log locally. Decode default data-area(s) in default format.
# nvme ocp internal-log /dev/nvme0 --string-log=ocp_string_log.bin •Retrieve OCP String Log, reads in the Telemetry
Host-Initiated Log locally. Decode data-areas 1 and 2, and output in json
format.
# nvme ocp internal-log /dev/nvme0 --telemetry-log=host_telemetry.bin •Reads in both OCP String Log and Telemetry
Host-Initiated Log locally. Decode data-areas 1 and 2, and output in normal
text format.
# nvme ocp internal-log /dev/nvme0 --string-log=ocp_string_log.bin NVMEPart of the nvme-user suite
|