Namemodbus_rtu_set_rts - set the RTS mode in RTU Synopsisint modbus_rtu_set_rts(modbus_t *ctx, int mode) DescriptionThe modbus_rtu_set_rts() function shall set the Request To Send mode to communicate on a RS485 serial bus. By default, the mode is set to MODBUS_RTU_RTS_NONE and no signal is issued before writing data on the wire. To enable the RTS mode, the values MODBUS_RTU_RTS_UP or MODBUS_RTU_RTS_DOWN must be used, these modes enable the RTS mode and set the polarity at the same time. When MODBUS_RTU_RTS_UP is used, an ioctl call is made with RTS flag enabled then data is written on the bus after a delay of 1 ms, then another ioctl call is made with the RTS flag disabled and again a delay of 1 ms occurs. The MODBUS_RTU_RTS_DOWN mode applies the same procedure but with an inverted RTS flag. This function can only be used with a context using a RTU backend. Return valueThe function shall return 0 if successful. Otherwise it shall return -1 and set errno to one of the values defined below. Errors
ExampleEnable the RTS mode with positive polarity: modbus_t *ctx; uint16_t tab_reg[10]; ctx = modbus_new_rtu("/dev/ttyS0", 115200, 'N', 8, 1); modbus_set_slave(ctx, 1); modbus_rtu_set_serial_mode(ctx, MODBUS_RTU_RS485); modbus_rtu_set_rts(ctx, MODBUS_RTU_RTS_UP); if (modbus_connect(ctx) == -1) { See also
|